Brand Name : VICTOR
Model Number : VICTOR 6056A+
Certification : CE
Place of Origin : CHINA
MOQ : 100pcs
Price : 100pcs: USD21.3/pc; 100pcs to 500pcs: USD20.2/pc; 500pcs to 1000pcs: USD19.2/pc; Above 3000pcs: USD18.2/pc
Payment Terms : T/T, Western Union, L/C,Paypal
Supply Ability : 10000 pc available
Delivery Time : 5-30 days
Packaging Details : Color box ,24pcs/Carton ,18KG/Carton
Color : Black and orange
Weight : Approx 410g
Packing : Color box
Display : 3999 Counts
Operation way : Auto range
Product size : 255×82×50mm
Battery : 9V(6F22)
LCD Size : 45*26mm
CE 3999 Counts Digital Clamp Multimeter For ACA ACV DCV Measuring
VICTOR 6056A+ Handheld 3999 Digital Clamp Meter With The Measuring Functions Of ACA, ACV, DCV, Resistance, Frequency, Temperature
1. General
It is a handheld digital Clamp Meter with the measuring functions of ACA, ACV, DCV, Resistance, Frequency, Temperature and etc., it could be used in Lab, family and other circumstance, where high current measurement is required.
2. Safety Note
The instrument’s design meets the standard of IEC1010-1 (EN61010-1) pollution 2, CAT.600V and UL3111-1. Please read the following before operation.
3. General Property
3-1-1. Display: LCD display 3-1-2. Max Display: 3999 (3 3/4) digit automatic polarity Display.
3-1-3. Max Jaw Opening: 51mm 3-1-4. Over range Indication: “OL” Display.
3-1-5. Hold: Date Hold, Peak Value Hold 3-1-6. DCA Auto Zero Adjustment
3-1-7. Sampling Rate: 3tims/second 3-1-8. Low Battery Indication
3-1-9. Continuity Test: Buzzer sounds at less than (50±20) Ω. 3-1-10.Auto Range
3-1-11. Auto Power Off 3-1-12.Power Consumption: Approx. 3 mA
3-1-13. Power Supply: 1pc 9V battery (IEC6LF22, NEDA1604 or JIS006P)
3-1-14. Operation Environment: 0-40℃, Relative Humidity: <70% RH.
3-1-15. Dimension: 260mm x 100mm x 50mm
3-1-16. Weight: Approx. 330g (including battery)
3-1-17. Accessory: Operation Manual, Gift Box, Test Leads, Temperature Probe TP01, 9V battery.
3-2 Technical Property
3-2-1. Technical Specification
3-2-1-1. Accuracy: ±(a% x reading + dgts) at (23±5) ℃, relative humidity <70%.
3-2-1-2. Temperature coefficient: 0.1 x specified accuracy/1℃ (<18℃ or >28℃)
4. Technical Data: VICTOR 6056A+
Basic Function | Range | Accuracy |
DC Voltage | 400mV/4V/40V/400V | ±(0.5%+4d) |
1000V | ±(1.0%+6d) | |
DC Current | 40A | ±(3%+8d) |
400A | ±(2.5%+8d) | |
1000A | ±(3%+10d) | |
AC Voltage | 400mV | ±(1.6%+8d) |
4V/40V/400V | ±(0.8%+10d) | |
750V | ±(1.0%+10d) | |
AC Current | 40A | ±(3%+10d) |
400A | ±(2.5%+8d) | |
1000A | ±(3%+10d) | |
Resistance | 400Ω | ±(0.8%+5d) |
4kΩ/40kΩ/400kΩ/4MΩ | ±(0.8%+4d) | |
40MΩ | ±(1.2%+10d) | |
Capacitance | 4nF | ±(3.5%+30d) |
40nF/400nF/4uF/40uF | ±(3.0%+10d) | |
100uF | ±(5.0%+10d) | |
Frequency | 9.999HZ/99.99HZ/999.9HZ/9.999kHz/99.99kHz | ±(0.5%+4d) |
![]() |